FKB, FKD & FKM Gauge, Differential and Absolute Pressure Transmitter for Remote Seal(s)
EDF “Not Classified” version and EDF “K3 Classified” version for Nuclear Applications
The FKB, FKD & FKM gauge, differential and absolute pressure transmitters for remote seal(s) accurately measure pressure and transmit a proportional 4-20 mA output signal.
The transmitter uses a unique micro-capacitive silicon sensor in combination with a state-of-the-art digital signal processing to provide exceptional performance in terms of accuracy and stability.
TECHNICAL SPECIFICATIONS
- Standards: K3/1E & K3-ad/1E
- Radiation tolerance: 20 krad / 5 Mrad
- Abnormally high temperature (LOCA): 85°C (185°F)
- Seismic: 35G
- Pressure ranges from 0.32 kPa up to 50000 kPa (0.04641 to 7251.89 psi)
- Accuracy: ±0.07% for differential and gauge pressure models and ±0.2% for absolute pressure models
- Stability:
- ±0.1% of URL for 3 years (FKB & FKD)
- ±0.2% of URL for 3 years (FKM)
- Output: 4-20 mA / HART
- Programmable output linearization in up to 14 points
- Burnout current functionality compliant with NAMUR NE43
- Dry calibration without reference pressure
APPLICATION FLEXIBILITY
- Full range of hazardous area approvals
- Built-in RFI filter and lightning arrester
- Analog indicator at either the electronics side or terminal side
- 5 digits LCD display with engineering units
- Stainless steel electronic housing
- Wide selection of wetted part materials
DOCUMENTATION