FKB, FKD & FKM Gauge, Differential and Absolute Pressure Transmitter for Remote Seal(s)

EDF “Not Classified” version and EDF “K3 Classified” version for Nuclear Applications

The FKB, FKD & FKM gauge, differential and absolute pressure transmitters for remote seal(s) accurately measure pressure and transmit a proportional 4-20 mA output signal.

The transmitter uses a unique micro-capacitive silicon sensor in combination with a state-of-the-art digital signal processing to provide exceptional performance in terms of accuracy and stability.

TECHNICAL SPECIFICATIONS
  • Standards: K3/1E & K3-ad/1E
  • Radiation tolerance: 20 krad / 5 Mrad
  • Abnormally high temperature (LOCA): 85°C (185°F)
  • Seismic: 35G
  • Pressure ranges from 0.32 kPa up to 50000 kPa (0.04641 to 7251.89 psi)
  • Accuracy: ±0.07% for differential and gauge pressure models and ±0.2% for absolute pressure models
  • Stability:
    • ±0.1% of URL for 3 years (FKB & FKD)
    • ±0.2% of URL for 3 years (FKM)
  • Output: 4-20 mA / HART
  • Programmable output linearization in up to 14 points
  • Burnout current functionality compliant with NAMUR NE43
  • Dry calibration without reference pressure
APPLICATION FLEXIBILITY
  • Full range of hazardous area approvals
  • Built-in RFI filter and lightning arrester
  • Analog indicator at either the electronics side or terminal side
  • 5 digits LCD display with engineering units
  • Stainless steel electronic housing
  • Wide selection of wetted part materials